AWS Single-Ply Roofing

Download PDFPRODUCT DATA SHEET

TPO Fleece-Back Membrane
45 Mil
60 Mil

DESCRIPTION

TPO Fleece-Back Membrane meets or exceeds all of the requirements for ASTM D 6878-03 Thermoplastic Polyolefin membrane. The Fleece-Back Membrane is reinforced with a 9 x 9, 1000 denier polyester fabric.

INSTALLATION

TPO fleece-back may be installed as a mechanically attached, a fully adhered, or a ballasted system.  Please consult current WeatherStar TPO specifications for specific application needs.

PREPARATION OF SUBSTRATES

Substrates must be clean, dry, smooth, and free of sharp edges, fins, loose or foreign materials, oil, grease, or other materials which may damage the membrane.

All rough surfaces which could damage the membrane shall be repaired as specified to offer a smooth substrate.

All surface voids greater than 1/4" (6.35 mm) wide shall be properly filled with an acceptable material.

STORAGE

Store in original, unopened packaging and away from sources of punctures and physical damage. 

Assure that structural decking will support the loads incurred by the material stored on roof top. The deck load limitations should be specified by the project designer.

SHELF LIFE

Not applicable.

PRECAUTIONARY DATA

To avoid sources of punctures and physical damage, take care when moving, transporting, or handling.

WARRANTY

American WeatherStar warrants that the material supplied will meet or exceed physical properties as published. The contractor guarantees that workmanship will be free of defects in coating application. Since performance of previously installed substrate is beyond the control of American WeatherStar or the contractor, requests for additional warranty coverage shall be subject to prior approval by American WeatherStar.

PHYSICAL PROPERTIES

PROPERTY

TEST METHOD

MINIMUM

TYPICAL VALUES

Thickness, min., mil (mm):

ASTM D 751

39 (0.99)

45 (1.14)

60 (1.52)

Thickness Over Scrim, mil (mm):

     45 (1.14):

     60 (1.52):

ASTM D 6878

Annex A1

12 (0.31)

 

15 (0.38)

22 (0.56)

Breaking Strength, min., lbf (N)

ASTM D 751

220 (976)

330 (1500)

Elongation at Reinforcement Break,
     min., %:

ASTM D 751

15

30

Tearing Strength, min., lbf (N):

ASTM D 751

55 (245)

156 (694)

Brittleness Point, max, ºF (ºC):

ASTM D 2137

Method B

-40 (-40)

-49 (-45)

Ozone Resistance, No Cracks:

ASTM D 1149

Pass

Pass

Properties After Heat Aging:
(retained values)

Breaking Strength, % min.:

Elongation at Reinforcement Break, % min.:

Tearing Strength, % min.:

Weight Change (mass), max %:

ASTM D 573


ASTM D 751


ASTM D 751

ASTM D 751

ASTM D 751



90


90

60

±1



90


90

60

-0.02

Linear Dimensional Change, max, %:

ASTM D 1204

±1

-0.01

Water Absorption, max, mass %:

ASTM D 471

±3

+1.2

Factory Seam Strength, lbf (N):

ASTM D 751

66 (290)

75 (330)

Accelerated Weathering:

ASTM G 151

ASTM G 155

Pass

Pass

Water Vapor Permeance – Perm:

E 96

N/A

0.0122

Puncture Resistance – lbf (N):

FTM 101C

Method 2031

200 (890)

337 (1500)



AWS Home | Single-Ply | Contractors | Facility Managers | Architects | Coatings | Spray Foam
ENERGY STAR® |
Certifications | Products | Application Specs | Case Studies | Warranties
Photo Gallery | Site Map | Contact Us

All content Copyright © 2004-2008 American WeatherStar

AWS Roofing Home Page
AWS Single-Ply Roofing for Contractors
AWS Single-Ply Roofing for Facility Managers
AWS Single-Ply Roofing for Architects
AWS Single-Ply Roofing Products Data
AWS Single-Ply Roofing Application Specifications
AWS Single-Ply Roofing Case Studies
AWS Single-Ply Roofing Long Term Warranties
Contact AWS Roofing
AWS Roof Coatings and Wall Coatings
AWS Spray Foam Insulation